Spirax Sarco 4037195, SC20 Sample Cooler w/ Ferru
Spirax Sarco Sample Cooler, SC20 Series, 1/2 in Condensate Inlet, Stainless Steel Body. The Spirax Sarco SC20 sample cooler is used to cool samples of boiler water or steam. The cooler consists of a stainless steel coil, through which the sample flows, and a stainless steel body, through which cooling water flows in the opposite direction.
DetailsSample Coolers - Mechatest Liquid and Gas Sampling Solutio
Applications in hot water sampling, Steam cycle for Makeup, Condensate, Deaerator, Boiler feedwater, Saturated steam, Main steam, Reheat steam, Superheated steam and Hydrocarbon fluids. Innovative sample cooling systems combined with expert sampling knowledge and fast distribution by Mechatest, an excellent combination.
DetailsSample Coolers | US | Spirax Sar
Spirax Sarco stainless steel Sample Coolers allows you to sample boiler water safely and accurately. We use cookies to give you the best experience on our website. If you continue without changing your cookie settings, we assume that you consent to our use of cookies on this device.
DetailsSC20 Sample Coolers - First for Steam Solutio
The Spirax Sarco SC20 sample cooler is used to cool samples of boiler water or steam. The cooler consists of a stainless steel coil, through which the sample flows, and a stainless steel body, through which cooling water flows in the opposite direction. A pre-drilled mounting bracket is …
DetailsLiquid Sample Coolers - Madden Engineered Produc
Sample cooler models have all the piping connections for the sample and the cooling water on the threaded cap on the top of the sample cooler. All coils are 1/4″ OD tubing, and all piping connections are 1/4″ NPT. Cooling water enters on the left and exits opposite on the right.
DetailsSample Cooler - EWT Water Technolo
Sample Cooler ← Home • Products • Sample Cooler ↓ Summary • Design Example • Applications • Technical Data • Downloads Summary: A sample cooler serves for safe sampling, cooling and if applicable condensation of hot fluids. The following descriptions are limited to water to water heat exchangers used in steam boiler plants and hot water boiler plants for the above purposes.
DetailsBoiler Sample Cooler - Ideal for Boiler and Steam Sampli
Boiler Blowdown Cooler Model Number CW-ESC-SS is used as a safe method of obtaining a water sample from boilers, feedwater lines, and steam lines. The specifications are as follows: Stainless Steel Shell; Stainless Steel End Caps; 1/4" NPT Stainless Steel Adaptors; Continuous 316 Stainless Steel Coil; Coil rated to 2,500 psi; Shall Rated to 250 psi
DetailsSteam Sampling 101: Basics and What Really Matte
2. Understand Steam Sampling Dynamics. A steam sampling system design differs from a gas phase sampling system and from a single-phase liquid sampling system. Steam changes state as its temperature and pressure change and these transitions must be accounted for to avoid inconsistent, non-representative results. As such, you should consider:
DetailsSTEAM SAMPLING SYSTEMS - WATER SAMPLING - SWAS
Steam Sample Conditioning and Collection. Sampling solutions for steam & water sampling.Sample Conditioning Panels built as per standard ASME PTC 19.11 and VGB/DGRL. For proper conditioning of your steam and water samples Steam apllications Demi Water, Feedwater, Condensate, Boiler Water, LP Drum Water, LP/HP Steam, Life Steam, Main Steam Demi Water, Feedwater, Condensate, Boiler Water…
DetailsLowe Engineering | Design and manufactures of contr
In steam sample which are less than 40 barA at the process, the sample flow may be limited by the pressure drop in the overall system. The superheat within the sample is assumed to be lost to ambient during transit to the cooler. For samples which are other than Steam or Water, please contact this office for specific conditions and applications.
DetailsWater Sample Coolers - Sampling Water in Boiler Plan
Stainless steel Shell. Welded to BS EN 287. Fixed coil. 10mm Stainless Steel coil type 1.00mm wall thickness, annealed condition. Suitable for pressures up to and including 139 bar @ 336 degrees C. Max. Working pressure for the shell 14 bar. Coolant inlet and outlet 1/2" b.s.p. Sample flow controlled by a 3/8" (10mm) valve. Cooling water by a 1
Details